EMC Host Connectivity with QLogic Fibre Channel and iSCSI (HBAs) and (CNAs) for the Linux Environment
Introduction
Zoning
When using Linux hosts in a fabric environment, the zoning must be
set up as single initiator and single target zoning. A single
initiator/single target zone is composed of one adapter and one EMC
storage array port. Storage array ports can be shared among adapters;
however, each adapter must be in its own zone.
Note: Multi-initiator zones are not recommended in a Linux fabric
environment.
EMC storage array-specific settings
Refer to the EMC Host Connectivity Guide for Linux, available at
http://Powerlink.EMC.com, for EMC storage array-specific settings.