Qlogic QLogic Fibre Channel Switch Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Commutateurs de réseau Qlogic QLogic Fibre Channel Switch. Qlogic QLogic Fibre Channel Switch User`s guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Event Message Guide

Simplify059060-00 A Page iQLogic Fibre Channel SwitchEvent Message GuideFirmware Version 4.0

Page 2 - Document Revision History

2 – Events and Event LoggingConfiguring Port Alarm Thresholds2-4 59060-00 0302.6Configuring Port Alarm ThresholdsYou can configure the switch to gene

Page 3 - Table of Contents

59060-00 03 3-1Section 3Event MessagesThis section lists event messages from the command line interface and SANbox Manager in message ID sequence by

Page 4 - User’s Guide

3 – Event MessagesAlarm Events3-2 59060-00 0303.1Alarm Events[A] [1003.0010] [Segmenting, zoneset zone_set_name not defined]Meaning: In non-interop m

Page 5 - Introduction

3 – Event MessagesAlarm Events59060-00 03 3-30[A] [1003.0015] [Zoneset Activation received from switch with domain domain_ID failed, unknown zoneset

Page 6 - Contact Information

3 – Event MessagesAlarm Events3-4 59060-00 030[A] [1003.001F] [Failing remote zoning configuration, member limit for zone zone_name exceeded, (size=n

Page 7 - Events and Event Logging

3 – Event MessagesAlarm Events59060-00 03 3-50[A] [1003.0041] [Zoning objects which contain Fibre Channel (FC) Address Members not being sent to remo

Page 8 - 2-2 59060-00 03

3 – Event MessagesAlarm Events3-6 59060-00 030[A] [1004.000C] [Eport Isolating due to Domain ID Locked, Domain ID unavailable]Meaning: An E_Port isol

Page 9 - Configuring the Event Log

3 – Event MessagesAlarm Events59060-00 03 3-70[A] [1004.0014] [Eport Isolating due to TOV Mismatch indicated on ELP]Meaning: An E_Port isolated becau

Page 10 - 2-4 59060-00 03

3 – Event MessagesAlarm Events3-8 59060-00 030[A] [1004.0029] [No Switch capable of being Principal Switch. Reconfigure Principal Switch Priority.]Me

Page 11 - Event Messages

3 – Event MessagesAlarm Events59060-00 03 3-90[A] [1004.0035] [Failed to connect to a switch due to incompatibility - check interop settings.]Meaning

Page 12 - Alarm Events

Page ii 59060-00 A0ProductName ProductTypeUser’s Guide© 2000–2004 QLogic CorporationFirst Printed: April 2004All Rights Reserved Worldwide.Printed in

Page 13 - 59060-00 03 3-3

3 – Event MessagesAlarm Events3-10 59060-00 030[A] [1005.0024] [Switch must be reset after leaving the Diagnostics Admin State]Meaning: After changin

Page 14 - 3-4 59060-00 03

3 – Event MessagesCritical Events59060-00 03 3-1103.2Critical Events[C] [8100.0001] [LOG_MASK_NAME_SERVER] [Port: port_number] [Protocol violation fr

Page 15 - 59060-00 03 3-5

3 – Event MessagesCritical Events3-12 59060-00 030[C] [8400.000B] [Switch] [The switch will be shutdown several seconds]Meaning: The switch will be s

Page 16 - 3-6 59060-00 03

3 – Event MessagesCritical Events59060-00 03 3-130[C] [8400.002F] [Switch] [Zoning database of over 3000 zone members may damage certain non-QLogic s

Page 17 - 59060-00 03 3-7

3 – Event MessagesCritical Events3-14 59060-00 030[C] [8600.0015] [PortApp] [Port: port_number] [Unresponsive device device_al_pa on port port_number

Page 18 - 3-8 59060-00 03

3 – Event MessagesWarning Events59060-00 03 3-1503.3Warning Events[W] [8400.0007] [Switch] [Attempted unauthenticated login username account_name]Mea

Page 19 - 59060-00 03 3-9

3 – Event MessagesWarning Events3-16 59060-00 030[W] [8700.000A] [EPort] [Port: port_number] [No response from remote switch, resetting Inter-Switch

Page 20 - 3-10 59060-00 03

3 – Event MessagesInformative Events59060-00 03 3-1703.4Informative Events[I] [8200.0002] [mserver] [Port: port_number] [Rejecting request from addre

Page 21 - Critical Events

3 – Event MessagesInformative Events3-18 59060-00 030[I] [8300.0004] [zoning] [New Active ZoneSet zone_set_name]Meaning: A new zone set has been acti

Page 22 - 3-12 59060-00 03

3 – Event MessagesInformative Events59060-00 03 3-190[I] [8600.0006] [PortApp] [Port: port_number] [Online test passed, done = iterations_done, req =

Page 23 - 59060-00 03 3-13

59060-00 03 Page iiiTable of ContentsSection 1 Introduction1.1 Intended Audience ...

Page 24 - 3-14 59060-00 03

3 – Event MessagesInformative Events3-20 59060-00 030[I] [8F00.0009] From SANbox Manager: Link AddedMeaning: The application fabric discovery process

Page 25 - Warning Events

Page iv 59060-00 03ProductName ProductTypeUser’s Guide0Notes

Page 26 - 3-16 59060-00 03

59060-00 03 1-1Section 1IntroductionThis manual describes the alarm messages for the SANbox 3050 Fibre Channel switch using firmware version 4.0:This

Page 27 - Informative Events

1 – IntroductionTechnical Support1-2 59060-00 0301.3Technical SupportCustomers should contact their authorized maintenance provider for technical sup

Page 28 - 3-18 59060-00 03

59060-00 03 2-1Section 2Events and Event LoggingMessages originate from the switch or from the SANbox Manager application in response to events that

Page 29 - 59060-00 03 3-19

2 – Events and Event LoggingDisplaying the Events Using the Command Line Interface2-2 59060-00 0302.3Displaying the Events Using the Command Line Int

Page 30 - 3-20 59060-00 03

2 – Events and Event LoggingConfiguring the Event Log59060-00 03 2-302.4Configuring the Event LogYou can customize what events that are recorded in t