4 – Installation
Installing a Switch
4-4 59096-02 C
S
CAUTION! If the switch is mounted in a closed or multi-unit rack assembly,
make sure that the operating temperature inside the rack enclosure
does not exceed the maximum rated ambient temperature. Refer
to ”Environmental” on page A-4.
Do not restrict chassis air flow. Allow 16 cm (6.5 in) minimum
clearance at the front and rear of the switch (surface mount) or
rack for service access and ventilation.
Multiple rack-mounted units connected to the AC supply circuit
may overload that circuit or overload the AC supply wiring.
Consider the power source capacity and the total power usage of
all switches on the circuit. Refer to ”Electrical” on page A-4.
Reliable grounding in the rack must be maintained from the switch
chassis to the AC power source.