Qlogic SANbox2-8c Guide de l'utilisateur Page 98

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 218
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 97
5 Managing Ports
Testing Ports
5-14 59022-05 A
5.3
Testing Ports
The port loopback tests verify correct port operation by sending a frame out
through the loop, and then verifying that the frame received matches the frame
that was sent. Only one port can be tested at a time for each type of test. The Port
Loopback Test window shown in Figure 5-4 presents the following tests:
SerDes level (Internal) - The SerDes level test verifies port circuitry. The
SerDes level test sends a test frame from the ASIC through the SerDes chip
and back to the ASIC for the selected ports. The port passes the test if the
frame that was sent by the ASIC matches the test frame that was received.
This test disrupts communication on the selected port.
SFP level (External) - The SFP level test also verifies port circuitry. The
SFP level test sends a test frame from the ASIC through the SerDes chip,
through the SFP transceiver fitted with a loopback plug, and back to the
ASIC for the selected ports. The port passes the test if the test frame that
was sent by the ASIC matches the test frame that was received. This test
disrupts communication on the selected port.
Node-to-Node (Online) - The Node-to-Node test verifies communications
between the port and its device node or device loop. The port being tested
must be online and connected to a remote device. The port passes the test if
the frame that was sent by the ASIC matches the frame that was received.
This test does not disrupt communication on the selected port.
Figure 5-4 Port Loopback Test Window