Qlogic SANblade 2300 Series Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Logiciel Qlogic SANblade 2300 Series. Qlogic SANblade 2300 Series User`s guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 278
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - Simplify

FC2354601-00 E Page iQSimplifySANblade 2300 Series User’s Guide2-Gb Fibre Channel to PCI-X Host Bus Adapters

Page 2 - Page ii FC2354601-00 E

SANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersPage x FC2354601-00 EQ11.4 Removing the Driver . . . . . . . . . . . . . . . .

Page 3 - FC2354601-00 E Page iii

8 – Windows NT Driver InstallationQLDIRECT8-6 FC2354601-00 EQ6. Click OK.7. Exit the REGEDT32 program, then restart the system.8.5QLDIRECTThe QLDIREC

Page 4

8 – Windows NT Driver InstallationQL2x00IP NDIS Network Driver InstallationFC2354601-00 E 8-7Q8.5.2.2Updating to QLDIRECT from QLFILTERThe QLDIRECT d

Page 5 - Table of Contents

8 – Windows NT Driver InstallationQL2x00IP NDIS Network Driver Installation8-8 FC2354601-00 EQn Release.txt—release notes for the QL2x00IP drivern Re

Page 6 - Section 4 QLA2342/2342L

8 – Windows NT Driver InstallationQL2x00IP NDIS Network Driver InstallationFC2354601-00 E 8-9Q8.6.2Updating the QL2x00IP NDIS Network DriverPerform t

Page 7 - Section 7 Troubleshooting

8 – Windows NT Driver InstallationQL2x00IP NDIS Network Driver Installation8-10 FC2354601-00 EQn MTU Size. This parameter specifies the maximum trans

Page 8 - Part II Software

8 – Windows NT Driver InstallationQL2x00IP NDIS Network Driver InstallationFC2354601-00 E 8-11Q3. On the IP Address tab, select the QLA23xx HBA, then

Page 9 - FC2354601-00 E Page ix

8 – Windows NT Driver InstallationQL2x00IP NDIS Network Driver Installation8-12 FC2354601-00 EQNotes

Page 10 - Section 14 Fast!UTIL

FC2354601-00 E 9-1Section 9 Windows 2000 Driver Installation(QL2300.SYS)9.1IntroductionThis section provides instructions for installing the Win

Page 11 - SANblade 2300 User’s Guide

9 – Windows 2000 Driver InstallationWindows 2000 Installation9-2 FC2354601-00 EQ9.3Windows 2000 InstallationPerform the installation instructions tha

Page 12 - Page xii FC2354601-00 E

9 – Windows 2000 Driver InstallationWindows 2000 InstallationFC2354601-00 E 9-3Q9.3.2Initial Installation of Windows 2000 and the Windows 2000 Driver

Page 13 - Figure Page

2-Gb Fibre Channel to PCI-XFC2354601-00 E Page xiQSANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus Adapters14.4 Fibre Disk Utility . .

Page 14 - Page xiv FC2354601-00 E

9 – Windows 2000 Driver InstallationWindows 2000 Installation9-4 FC2354601-00 EQ9.3.3Installing the Windows 2000 DriverThe QLA23xx HBAs are plug-and-

Page 15 - FC2354601-00 E Page xv

9 – Windows 2000 Driver InstallationWindows 2000 InstallationFC2354601-00 E 9-5QChannel Adapter message displays. Perform the following steps to comp

Page 16 - Table Page

9 – Windows 2000 Driver InstallationRemoving the Windows 2000 Driver9-6 FC2354601-00 EQ8. When the Upgrade Device Driver Wizard/Select a Device Drive

Page 17 - FC2354601-00 E Page xvii

9 – Windows 2000 Driver InstallationSystem Registry ParametersFC2354601-00 E 9-7QNOTE: OEMSETUP.INF automatically updates the registry to support 33

Page 18 - Page xviii FC2354601-00 E

9 – Windows 2000 Driver InstallationQLDIRECT9-8 FC2354601-00 EQFollow these steps to change the UseSameNN parameter:1. Click Start, select Run, and o

Page 19

9 – Windows 2000 Driver InstallationQLDIRECTFC2354601-00 E 9-9Q9.6.2QLDIRECT InstallationIf QLDIRECT is not installed on your system, perform the ins

Page 20 - Features

9 – Windows 2000 Driver InstallationQL2x00IP NDIS Network Driver Installation9-10 FC2354601-00 EQ9.7QL2x00IP NDIS Network Driver InstallationYour sys

Page 21 - Hardware

9 – Windows 2000 Driver InstallationQL2x00IP NDIS Network Driver InstallationFC2354601-00 E 9-11Q11. Click OK.12. In the Network Adapter list, click

Page 22 - I-2 FC2354601-00 E

9 – Windows 2000 Driver InstallationQL2x00IP NDIS Network Driver Installation9-12 FC2354601-00 EQThe QL2x00IP NDIS driver provides drive configuratio

Page 23 - QLA2310/2310F/2310FL

9 – Windows 2000 Driver InstallationQL2x00IP NDIS Network Driver InstallationFC2354601-00 E 9-13QPerform the following steps to make QL2x00IP NDIS dr

Page 24 - 2-2 FC2354601-00 E

SANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersPage xii FC2354601-00 EQ16.4 Configuring HBAs in SANblade Control FX Wizard .

Page 25 - Power Distribution

9 – Windows 2000 Driver InstallationQL2x00IP NDIS Network Driver Installation9-14 FC2354601-00 EQ4. In the Choose a Hardware Task dialog box, click U

Page 26 - Installation in the Computer

FC2354601-00 E 10-1Section 10 Windows XP Driver Installation(QL2300.SYS)10.1IntroductionThis section provides instructions for installing the Wi

Page 27 - Installation Help

10 – Windows XP Driver InstallationInstalling the Windows XP Driver10-2 FC2354601-00 EQ10.3Installing the Windows XP DriverPerform the installation i

Page 28 - 2-6 FC2354601-00 E

10 – Windows XP Driver InstallationInstalling the Windows XP DriverFC2354601-00 E 10-3Q10.3.2Initial Installation of Windows XP and the Windows XP Dr

Page 29

10 – Windows XP Driver InstallationInstalling the Windows XP Driver10-4 FC2354601-00 EQ10.3.3Installing the Windows XP DriverThe QLA23xx HBAs are plu

Page 30

10 – Windows XP Driver InstallationInstalling the Windows XP DriverFC2354601-00 E 10-5QIf the Windows XP driver has already been installed and you ar

Page 31 - Selecting the Boot Device

10 – Windows XP Driver InstallationRemoving the Driver10-6 FC2354601-00 EQ7. Insert the driver disk created in section 10.2. Click Have Disk.8. In th

Page 32 - Building the Bootable Disk

10 – Windows XP Driver InstallationSystem Registry ParametersFC2354601-00 E 10-7Q10.5.1MaximumSGListWindows XP includes enhanced scatter/gather list

Page 33

10 – Windows XP Driver InstallationSystem Registry Parameters10-8 FC2354601-00 EQIf you want to have the world wide node name for each HBA to be base

Page 34

FC2354601-00 E 11-1Section 11 NetWare Driver Installation(QL2300.HAM)11.1IntroductionThis section provides instructions for installing the NetWa

Page 35 - Specifications

2-Gb Fibre Channel to PCI-XFC2354601-00 E Page xiiiQSANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersSection 18 SANblade Contro

Page 36 - EMI and EMC Requirements

11 – NetWare Driver InstallationInstalling the Driver11-2 FC2354601-00 EQ11.3Installing the DriverNOTE:n Novell no longer supports version 4.2. If yo

Page 37 - Product Safety Requirements

11 – NetWare Driver InstallationInstalling the DriverFC2354601-00 E 11-3Q4. Follow the standard NetWare instructions to begin the installation.When p

Page 38 - QLA2310F

11 – NetWare Driver InstallationInstalling the Driver11-4 FC2354601-00 EQ5. Select Select an additional driver.6. Press INSERT to install an unlisted

Page 39 - QLA2310FL

11 – NetWare Driver InstallationDriver ParametersFC2354601-00 E 11-5Q11.4Removing the DriverFollow these steps to remove the NetWare driver:1. From t

Page 40

11 – NetWare Driver InstallationDriver Parameters11-6 FC2354601-00 EQ/LUNS Instance This parameter tells NetWare to scan for all LUNs when this drive

Page 41 - QLA2340/2340L

11 – NetWare Driver InstallationDriver ParametersFC2354601-00 E 11-7Q/BACKOFF Global This parameter disables failback of I/O after a broken link or a

Page 42

11 – NetWare Driver InstallationDriver Parameters11-8 FC2354601-00 EQ/INQUIRY Instance This parameter forces the use of SCSI Inquiry commands during

Page 43 - FC2354601-00 E 3-3

11 – NetWare Driver InstallationDriver ParametersFC2354601-00 E 11-9Q11.5.2NVRAM ParametersThe QLogic HBA NVRAM settings are modified by entering Fas

Page 44

11 – NetWare Driver InstallationDriver Parameters11-10 FC2354601-00 EQNOTE: The timeout for loop/link/port down is set (in seconds) by the Port Down

Page 45 - FC2354601-00 E 3-5

FC2354601-00 E 12-1Section 12 Red Hat Linux Driver Installation12.1IntroductionThis section provides instructions for installing the Red Hat Lin

Page 46

SANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersPage xiv FC2354601-00 EQ2-4 QLA2310/2310F/2310FL HBA LED Activity . . . . . .

Page 47

12 – Red Hat Linux Driver InstallationInstalling the Driver12-2 FC2354601-00 EQ12.3.1Building a Custom Kernel to Load the Driver AutomaticallyThe ker

Page 48

12 – Red Hat Linux Driver InstallationInstalling the DriverFC2354601-00 E 12-3QAdd the following lines below it:subdir-$(CONFIG_SCSI_QLOGIC_QLA2XXX)

Page 49

12 – Red Hat Linux Driver InstallationInstalling the Driver12-4 FC2354601-00 EQ4. Remove any reference to older QLogic FC drivers.To ensure that the

Page 50

12 – Red Hat Linux Driver InstallationInstalling the DriverFC2354601-00 E 12-5QAfter building a UP or SMP version of the driver, you must load the dr

Page 51

12 – Red Hat Linux Driver InstallationInstalling the Driver12-6 FC2354601-00 EQAfter building a UP version of the driver, you must load the driver by

Page 52

12 – Red Hat Linux Driver InstallationInstalling the DriverFC2354601-00 E 12-7Q5. Create a new directly, /qla2x00. Using the driver disk created in s

Page 53

12 – Red Hat Linux Driver InstallationInstalling the Driver12-8 FC2354601-00 EQFor Redhat distributions 7.2 with kernel 2.4.9-21 and above, type the

Page 54

12 – Red Hat Linux Driver InstallationSystem Driver Parameter max_scsi_lunsFC2354601-00 E 12-9Q4. Configure the boot loader with the new RAMDISK imag

Page 55 - QLA2342/2342L

12 – Red Hat Linux Driver InstallationDriver Command Line Parameters12-10 FC2354601-00 EQFor GRUB, perform the following steps:1. Append the max_scsi

Page 56

FC2354601-00 E 13-1Section 13 Solaris SPARC Driver and SANblade Control FX Installation(QL2300)13.1IntroductionThis section provides instruction

Page 57 - FC2354601-00 E 4-3

2-Gb Fibre Channel to PCI-XFC2354601-00 E Page xvQSANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus Adapters16-8 Exit Wizard Screen . .

Page 58

13 – Solaris SPARC Driver and SANblade Control FX InstallationPre-installation Requirements for SANblade Control FX13-2 FC2354601-00 EQ13.3Pre-instal

Page 59 - FC2354601-00 E 4-5

13 – Solaris SPARC Driver and SANblade Control FX InstallationInstalling the Solaris SPARC Driver and SANblade Control FX from the QLogic WebSiteFC235

Page 60

13 – Solaris SPARC Driver and SANblade Control FX InstallationInstalling the Solaris SPARC Driver and SANblade Control FX from the QLogic Web Site13-4

Page 61

13 – Solaris SPARC Driver and SANblade Control FX InstallationInstalling the Solaris SPARC Driver and SANblade Control FX from the QLogic WebSiteFC235

Page 62

13 – Solaris SPARC Driver and SANblade Control FX InstallationFCode13-6 FC2354601-00 EQ14. Type y and press ENTER to continue the driver installation

Page 63

FC2354601-00 E III-1Part III ApplicationsThis part of the SANblade 2300 User’s Guide describes the Fast!UTIL BIOS utility, which allows advanced

Page 64

III – ApplicationsIII-2 FC2354601-00 EQn An overview of the SANblade Control FX Application (screens)n Instructions on using the SANblade Control FX

Page 65

FC2354601-00 E 14-1Section 14 Fast!UTILNOTE: The Fast!UTIL BIOS utility does not run on SunSPARC systems. Refer to the appropriate FCode section

Page 66

14 – Fast!UTILConfiguration Settings14-2 FC2354601-00 EQ14.2.1Host Adapter SettingsFrom the Configuration Settings menu in Fast!UTIL, select Host Ada

Page 67

14 – Fast!UTILConfiguration SettingsFC2354601-00 E 14-3Qn Connection Options. This setting defines the type of connection (loop or point-to-point) or

Page 68

SANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersPage xvi FC2354601-00 EQ19-7 Launch Application Dialog Box . . . . . . . . . .

Page 69 - QLA2344 HBA Components

14 – Fast!UTILConfiguration Settings14-4 FC2354601-00 EQChannel Device menu. The selected device displays in the Selectable Boot menu list.Repeat ste

Page 70

14 – Fast!UTILConfiguration SettingsFC2354601-00 E 14-5Qn Execution Throttle. This setting specifies the maximum number of commands executing on any

Page 71

14 – Fast!UTILScan Fibre Channel Devices14-6 FC2354601-00 EQn RIO Operation Mode. This setting specifies the reduced operation (RIO) modes, if suppor

Page 72

14 – Fast!UTILSelect Host AdapterFC2354601-00 E 14-7Q14.6Select Host AdapterIf you have multiple QLA23xx HBAs in your system, use this setting to sel

Page 73 - FC2354601-00 E 5-5

14 – Fast!UTILSelect Host Adapter14-8 FC2354601-00 EQNotes

Page 74

FC2354601-00 E 15-1Section 15 SANblade Control FX Application for Solaris15.1IntroductionThe SANblade Control FX (Application and Wizard) GUI fo

Page 75

15 – SANblade Control FX Application for SolarisExiting SANblade Control FX Application15-2 FC2354601-00 EQ15.3Exiting SANblade Control FX Applicatio

Page 76

15 – SANblade Control FX Application for SolarisMain Window and Window NavigationFC2354601-00 E 15-3QThe menu bar has three options:n Fileq Exit. Sel

Page 77

15 – SANblade Control FX Application for SolarisMain Window and Window Navigation15-4 FC2354601-00 EQ15.4.1HBA Tabbed PagesWhen you click an adapter

Page 78

15 – SANblade Control FX Application for SolarisMain Window and Window NavigationFC2354601-00 E 15-5Q15.4.1.1HBA Information Tabbed PageBy default, t

Page 79

2-Gb Fibre Channel to PCI-XFC2354601-00 E Page xviiQSANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus Adapters14-3 Advanced Adapter Sett

Page 80

15 – SANblade Control FX Application for SolarisMain Window and Window Navigation15-6 FC2354601-00 EQFigure 15-3. HBA Options Tabbed Page (Host Param

Page 81

15 – SANblade Control FX Application for SolarisMain Window and Window NavigationFC2354601-00 E 15-7QFigure 15-5. HBA Options Tabbed Page (Advanced F

Page 82

15 – SANblade Control FX Application for SolarisMain Window and Window Navigation15-8 FC2354601-00 EQ15.4.1.3Target Settings Tabbed PageThe Target Se

Page 83 - QLA2350/2352

15 – SANblade Control FX Application for SolarisMain Window and Window NavigationFC2354601-00 E 15-9Q15.4.1.4Boot Device Tabbed PageThe Boot Device t

Page 84

15 – SANblade Control FX Application for SolarisMain Window and Window Navigation15-10 FC2354601-00 EQ15.4.1.5Diagnostics Tabbed PageThe Diagnostics

Page 85

15 – SANblade Control FX Application for SolarisMain Window and Window NavigationFC2354601-00 E 15-11QFigure 15-9. Diagnostics Tabbed Page (Read/Writ

Page 86 - 6-4 FC2354601-00 E

15 – SANblade Control FX Application for SolarisMain Window and Window Navigation15-12 FC2354601-00 EQ15.4.1.6Utilities Tabbed PageThe Utilities tabb

Page 87

15 – SANblade Control FX Application for SolarisMain Window and Window NavigationFC2354601-00 E 15-13QFigure 15-11. Utilities Tabbed Page (Update FCo

Page 88

15 – SANblade Control FX Application for SolarisMain Window and Window Navigation15-14 FC2354601-00 EQ15.4.2.1Device Information Tabbed PageThe devic

Page 89

15 – SANblade Control FX Application for SolarisMain Window and Window NavigationFC2354601-00 E 15-15Q15.4.2.2Device LUN List Tabbed PageThe top of t

Page 90

SANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersPage xviii FC2354601-00 EQNotes

Page 91 - Troubleshooting

15 – SANblade Control FX Application for SolarisDisplaying Host, HBAs, Devices, LUNs, and Boot Devices15-16 FC2354601-00 EQ15.4.3LUN Information Tabb

Page 92 - 7-2 FC2354601-00 E

15 – SANblade Control FX Application for SolarisDisplaying Host, HBAs, Devices, LUNs, and Boot DevicesFC2354601-00 E 15-17Q15.5.2Displaying HBA Infor

Page 93 - Software

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-18 FC2354601-00 EQAnother way to display LUN information is to click on a LUN

Page 94 - II-2 FC2354601-00 E

15 – SANblade Control FX Application for SolarisConfigurating the HBAFC2354601-00 E 15-19QThe top of the HBA Options tabbed page contains is read-onl

Page 95

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-20 FC2354601-00 EQ15.6.1.1Host ParametersThe host parameters are illustrated

Page 96 - 8-2 FC2354601-00 E

15 – SANblade Control FX Application for SolarisConfigurating the HBAFC2354601-00 E 15-21Qn Frame Size. This setting specifies the maximum frame leng

Page 97

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-22 FC2354601-00 EQ15.6.1.2Advanced Host ParametersThis part of the HBA Option

Page 98

15 – SANblade Control FX Application for SolarisConfigurating the HBAFC2354601-00 E 15-23Qn Persistent Bind HBA. Select this check box to bind the se

Page 99

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-24 FC2354601-00 EQ15.6.1.3Advanced Firmware ParametersThis part of the HBA Op

Page 100 - QLDIRECT Installation

15 – SANblade Control FX Application for SolarisConfigurating the HBAFC2354601-00 E 15-25Qn Enable ACK0. This setting determines the type of ACK used

Page 101 - FC2354601-00 E 8-7

FC2354601-00 E 1-1Section 1 Introduction1.1How to Use this GuideThe SANblade QLogic host bus adapters (HBAs) supported in this document are desc

Page 102

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-26 FC2354601-00 EQ15.6.2Bind Devices Attached to the HBAsBind target devices

Page 103 - Driver Configuration

15 – SANblade Control FX Application for SolarisConfigurating the HBAFC2354601-00 E 15-27QThe binding information for target devices is in the table

Page 104 - IP Address Configuration

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-28 FC2354601-00 EQControl FX Application detects the target devices that are

Page 105

15 – SANblade Control FX Application for SolarisConfigurating the HBAFC2354601-00 E 15-29QThe loopback test is internal to the HBA. It is a tool to e

Page 106 - 8-12 FC2354601-00 E

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-30 FC2354601-00 EQread/write is also compared. If errors occur, the test indi

Page 107 - (QL2300.SYS)

15 – SANblade Control FX Application for SolarisConfigurating the HBAFC2354601-00 E 15-31Qn Test Results. This section displays the results after the

Page 108 - Windows 2000 Installation

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-32 FC2354601-00 EQ15.6.4.1Update the NVRAMWhen you click the Utilities tabbed

Page 109

15 – SANblade Control FX Application for SolarisConfigurating the HBAFC2354601-00 E 15-33Q15.6.4.2Update the FCodeWhen you click the Utilities tabbed

Page 110

15 – SANblade Control FX Application for SolarisConfigurating the HBA15-34 FC2354601-00 EQNotes

Page 111

FC2354601-00 E 16-1Section 16 SANblade Control FX Wizard for Solaris16.1IntroductionThe SANblade Control FX Wizard provides step-by-step procedu

Page 112 - MaximumSGList

SANblade 2300 Series User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersQPage ii FC2354601-00 EInformation furnished in this manual is believed

Page 113 - UseSameNN

1 – IntroductionWhat is Fibre Channel?1-2 FC2354601-00 EQ(PLDA) and fabric loop attach (FLA). Installation of the QLA23xx HBA is quick and easy.1.3Wh

Page 114

16 – SANblade Control FX Wizard for SolarisScreen Navigation16-2 FC2354601-00 EQ16.3Screen NavigationWhen you launch the SANblade Control FX Wizard,

Page 115

16 – SANblade Control FX Wizard for SolarisConfiguring HBAs in SANblade Control FX WizardFC2354601-00 E 16-3Q16.4.2Select an HBA to ConfigureIf you c

Page 116 - A:\W2k\Ip

16 – SANblade Control FX Wizard for SolarisConfiguring HBAs in SANblade Control FX Wizard16-4 FC2354601-00 EQ16.4.3Verify HBA and Driver InformationA

Page 117

16 – SANblade Control FX Wizard for SolarisConfiguring HBAs in SANblade Control FX WizardFC2354601-00 E 16-5Q16.4.4Update the HBA Connection Settings

Page 118

16 – SANblade Control FX Wizard for SolarisConfiguring HBAs in SANblade Control FX Wizard16-6 FC2354601-00 EQ16.4.5Perform Target BindingAfter select

Page 119

16 – SANblade Control FX Wizard for SolarisConfiguring HBAs in SANblade Control FX WizardFC2354601-00 E 16-7Qn Target ID. This column displays the ta

Page 120 - 9-14 FC2354601-00 E

16 – SANblade Control FX Wizard for SolarisConfiguring HBAs in SANblade Control FX Wizard16-8 FC2354601-00 EQIf you want to save a copy of the config

Page 121

16 – SANblade Control FX Wizard for SolarisConfiguring HBAs in SANblade Control FX WizardFC2354601-00 E 16-9Q16.4.8Exit Wizard ModeIf you selected th

Page 122 - 10-2 FC2354601-00 E

16 – SANblade Control FX Wizard for SolarisConfiguring HBAs in SANblade Control FX Wizard16-10 FC2354601-00 EQNotes

Page 123

FC2354601-00 E 17-1Section 17 SANblade Control FX Application for Windows NT/Windows 200017.1IntroductionNOTE: If you have installed a QLA2350/2

Page 124

FC2354601-00 E I-1Part I HardwareThis part of the SANblade 2300 User’s Guide describes the host bus adapters (HBAs) and how to install and confi

Page 125

17 – SANblade Control FX Application for Windows NT/ Windows 2000Getting Started17-2 FC2354601-00 EQPerform the following steps to install SANblade C

Page 126 - Removing the Driver

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window NavigationFC2354601-00 E 17-3QWhen the SANblade Control FX Ap

Page 127

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window Navigation17-4 FC2354601-00 EQn Toolsq Run Wizard. Select thi

Page 128 - ;UseSameNN=0

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window NavigationFC2354601-00 E 17-5Q17.5.1HBA Tabbed PagesWhen you

Page 129 - NetWare Driver Installation

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window Navigation17-6 FC2354601-00 EQ17.5.1.1HBA Information Tabbed

Page 130 - Connects to the Boot Device)

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window NavigationFC2354601-00 E 17-7Q17.5.1.2HBA Options Tabbed Page

Page 131 - Connects to an Add-On Device)

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window Navigation17-8 FC2354601-00 EQFigure 17-4. HBA Options Tabbed

Page 132

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window NavigationFC2354601-00 E 17-9QFigure 17-5. HBA Options Tabbed

Page 133 - System Parameters

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window Navigation17-10 FC2354601-00 EQ17.5.1.3Target Settings Tabbed

Page 134

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window NavigationFC2354601-00 E 17-11QTo view the target settings at

Page 135

I – HardwareI-2 FC2354601-00 EQNotes

Page 136

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window Navigation17-12 FC2354601-00 EQ17.5.1.4Diagnostics Tabbed Pag

Page 137 - NVRAM Parameters

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window NavigationFC2354601-00 E 17-13QFigure 17-9. Diagnostics Tabbe

Page 138

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window Navigation17-14 FC2354601-00 EQ17.5.1.5Utilities Tabbed PageT

Page 139 - Introduction

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window NavigationFC2354601-00 E 17-15QFigure 17-11. Utilities Tabbed

Page 140

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window Navigation17-16 FC2354601-00 EQ17.5.2.1Target Information Tab

Page 141

17 – SANblade Control FX Application for Windows NT/ Windows 2000Main Window and Window NavigationFC2354601-00 E 17-17Q17.5.2.2LUN List Tabbed PageTh

Page 142

17 – SANblade Control FX Application for Windows NT/ Windows 2000Displaying Host, HBAs, Devices, and LUNs17-18 FC2354601-00 EQ17.5.3LUN Information T

Page 143 - 12.3.2.1

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-19Q17.6.2Displaying HBA InformationClick on a

Page 144 - 12.3.2.2

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-20 FC2354601-00 EQn Perform loopback and read/write buffer t

Page 145 - Loading the Driver Manually

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-21Q17.7.1.1Host ParametersThe host parameters

Page 146 - 12.3.2.4

FC2354601-00 E 2-1Section 2 QLA2310/2310F/2310FL2.1QLA2310/2310F/2310FL HBA ComponentsFigures 2-1 through 2-3 identify the QLA23xx HBA component

Page 147

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-22 FC2354601-00 EQn Frame Size. This setting specifies the m

Page 148 - Proc Filesystem Support

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-23Q17.7.1.2Advanced Host ParametersThis part

Page 149 - (QL2300)

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-24 FC2354601-00 EQn Extended Logging. When you select this c

Page 150 - 13-2 FC2354601-00 E

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-25Qq Multiple responses, 16-bit handles, dela

Page 151 - QLogic Web Site

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-26 FC2354601-00 EQ17.7.2Bind Target Devices Attached to the

Page 152

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-27QThe binding information for target devices

Page 153

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-28 FC2354601-00 EQIf a multiport target does not comply with

Page 154

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-29QComplete binding the target IDs by clickin

Page 155 - Applications

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-30 FC2354601-00 EQThe read/write buffer test sends data thro

Page 156 - III-2 FC2354601-00 E

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-31QTo perform a loopback or a read-write buff

Page 157 - Fast!UTIL

2 – QLA2310/2310F/2310FLQLA2310/2310F/2310FL HBA Components2-2 FC2354601-00 EQFigure 2-2. QLA2310F HBA LayoutFigure 2-3. QLA2310FL HBA LayoutISP CHIP

Page 158 - Host Adapter Settings

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-32 FC2354601-00 EQ17.7.4Update the NVRAM and BIOSUpdate the

Page 159 - Selectable Boot Settings

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-33QPerform the following steps to update the

Page 160 - Advanced Adapter Settings

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-34 FC2354601-00 EQ17.7.4.2Updating the BIOSWhen you click th

Page 161

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBAFC2354601-00 E 17-35QThe SANblade Control FX Application checks

Page 162 - Loopback Data Test

17 – SANblade Control FX Application for Windows NT/ Windows 2000Configurating the HBA17-36 FC2354601-00 EQNotes

Page 163 - Select Host Adapter

FC2354601-00 E 18-1Section 18 SANblade Control FX Wizard for Windows NT/Windows 200018.1IntroductionThe SANblade Control FX Wizard provides step

Page 164 - 14-8 FC2354601-00 E

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Screen Navigation18-2 FC2354601-00 EQ18.3Screen NavigationWhen you launch the SANblade Co

Page 165 - Getting Started

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Configuring HBAs in SANblade Control FX WizardFC2354601-00 E 18-3Q18.4.1Review the Config

Page 166 - 15-2 FC2354601-00 E

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Configuring HBAs in SANblade Control FX Wizard18-4 FC2354601-00 EQFrom this screen, selec

Page 167 - FC2354601-00 E 15-3

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Configuring HBAs in SANblade Control FX WizardFC2354601-00 E 18-5Qn Firmware versionn Fai

Page 168 - HBA Tabbed Pages

2 – QLA2310/2310F/2310FLQLA2310/2310F/2310FL HBA ComponentsFC2354601-00 E 2-3Q2.1.1LEDsFigure 2-4 identifies and describes the activity of the QLA231

Page 169 - HBA Options Tabbed Page

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Configuring HBAs in SANblade Control FX Wizard18-6 FC2354601-00 EQSelect the data rate. T

Page 170 - 15-6 FC2354601-00 E

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Configuring HBAs in SANblade Control FX WizardFC2354601-00 E 18-7Qn The Enable column con

Page 171 - FC2354601-00 E 15-7

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Configuring HBAs in SANblade Control FX Wizard18-8 FC2354601-00 EQIf you want to save thi

Page 172 - Target Settings Tabbed Page

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Configuring HBAs in SANblade Control FX WizardFC2354601-00 E 18-9QIf you do not want to c

Page 173 - Boot Device Tabbed Page

18 – SANblade Control FX Wizard for Windows NT/ Windows 2000Configuring HBAs in SANblade Control FX Wizard18-10 FC2354601-00 EQ18.4.8FinishIf you sel

Page 174 - Diagnostics Tabbed Page

FC2354601-00 E 19-1Section 19 SANblade Control VIX Application for Windows 200019.1IntroductionThe SANblade Control VIX Application allows you t

Page 175 - FC2354601-00 E 15-11

19 – SANblade Control VIX Application for Windows 2000Installing SANblade Control VIX19-2 FC2354601-00 EQPerform the following steps to install the S

Page 176 - Utilities Tabbed Page

19 – SANblade Control VIX Application for Windows 2000Installing SANblade Control VIXFC2354601-00 E 19-3Q4. The Important Information dialog box disp

Page 177 - Device Tabbed Pages

19 – SANblade Control VIX Application for Windows 2000Installing SANblade Control VIX19-4 FC2354601-00 EQIf you do not have the VI Kernel Agent Drive

Page 178 - 15-14 FC2354601-00 E

19 – SANblade Control VIX Application for Windows 2000Installing SANblade Control VIXFC2354601-00 E 19-5Q7. The Pre-Installation Summary dialog box d

Page 179 - Device LUN List Tabbed Page

2 – QLA2310/2310F/2310FLInstallation in the Computer2-4 FC2354601-00 EQ2.2Installation in the ComputerPerform the following steps to install the QLA2

Page 180 - Displaying Host Information

19 – SANblade Control VIX Application for Windows 2000Installing SANblade Control VIX19-6 FC2354601-00 EQ9. The Launch Application dialog box display

Page 181 - Displaying HBA Information

19 – SANblade Control VIX Application for Windows 2000Main Window and Window NavigationFC2354601-00 E 19-7QIf you selected the Launch Application che

Page 182 - Configure the HBAs

19 – SANblade Control VIX Application for Windows 2000Main Window and Window Navigation19-8 FC2354601-00 EQWhen the SANblade Control FX Application s

Page 183 - FC2354601-00 E 15-19

19 – SANblade Control VIX Application for Windows 2000Main Window and Window NavigationFC2354601-00 E 19-9Qnumber. For example, if a host contains a

Page 184 - Host Parameters

19 – SANblade Control VIX Application for Windows 2000Main Window and Window Navigation19-10 FC2354601-00 EQ19.5.1.2VI Tabbed PageThe host VI tabbed

Page 185 - FC2354601-00 E 15-21

19 – SANblade Control VIX Application for Windows 2000Main Window and Window NavigationFC2354601-00 E 19-11Qn World wide port name of HBAn Port ID of

Page 186 - Advanced Host Parameters

19 – SANblade Control VIX Application for Windows 2000Main Window and Window Navigation19-12 FC2354601-00 EQ19.5.2.2Link Status Tabbed PageThe Link S

Page 187 - FC2354601-00 E 15-23

19 – SANblade Control VIX Application for Windows 2000Main Window and Window NavigationFC2354601-00 E 19-13Q19.5.2.3Settings Tabbed PageThe Settings

Page 188 - Advanced Firmware Parameters

19 – SANblade Control VIX Application for Windows 2000Main Window and Window Navigation19-14 FC2354601-00 EQ19.5.2.4VI Tabbed PageUse the VI tabbed p

Page 189 - FC2354601-00 E 15-25

19 – SANblade Control VIX Application for Windows 2000Main Window and Window NavigationFC2354601-00 E 19-15Q19.5.2.5Diagnostics Tabbed PageThe Diagno

Page 190 - 15-26 FC2354601-00 E

2 – QLA2310/2310F/2310FLInstallation in the ComputerFC2354601-00 E 2-5Q8. Connect the appropriate cable from the devices to the corresponding connect

Page 191 - FC2354601-00 E 15-27

19 – SANblade Control VIX Application for Windows 2000Enable VI and Assign IP Addresses19-16 FC2354601-00 EQ19.6Enable VI and Assign IP AddressesAfte

Page 192 - 15-28 FC2354601-00 E

19 – SANblade Control VIX Application for Windows 2000Enable VI and Assign IP AddressesFC2354601-00 E 19-17QRepeat these steps for each HBA in your s

Page 193 - FC2354601-00 E 15-29

19 – SANblade Control VIX Application for Windows 2000Enable VI and Assign IP Addresses19-18 FC2354601-00 EQ3. Click the VI tab. The VI tabbed page d

Page 194 - 15-30 FC2354601-00 E

19 – SANblade Control VIX Application for Windows 2000Configuring the HostFC2354601-00 E 19-19Q19.7Configuring the HostAfter enabling VI on the HBAs,

Page 195 - Update the NVRAM and FCode

19 – SANblade Control VIX Application for Windows 2000Configuring the Host19-20 FC2354601-00 EQn Max Registered MBytes. This parameter specifies the

Page 196 - Update the NVRAM

19 – SANblade Control VIX Application for Windows 2000Configurating the NVRAM ParametersFC2354601-00 E 19-21Q19.8Configurating the NVRAM ParametersTh

Page 197 - Update the FCode

19 – SANblade Control VIX Application for Windows 2000Performing Diagnostics19-22 FC2354601-00 EQn Operation Mode. This setting specifies the reduced

Page 198 - 15-34 FC2354601-00 E

19 – SANblade Control VIX Application for Windows 2000Performing DiagnosticsFC2354601-00 E 19-23QTo perform diagnostics, follow these steps on both S

Page 199

19 – SANblade Control VIX Application for Windows 2000Performing Diagnostics19-24 FC2354601-00 EQ8. The test results are displayed on the client and

Page 200 - Screen Navigation

2 – QLA2310/2310F/2310FLFCode2-6 FC2354601-00 EQIf you have a selectable boot BIOS and want to boot to an FC hard disk, set the motherboard BIOS para

Page 201 - Select an HBA to Configure

2 – QLA2310/2310F/2310FLFCodeFC2354601-00 E 2-7QPerform the following steps to run the flash utility:1. Copy the qla2x00flash file and the ifp2300.pr

Page 202 - 16-4 FC2354601-00 E

SANblade 2300 Series User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersQFC2354601-00 E Page iiiClarified description of the following QLA2300.H

Page 203 - FC2354601-00 E 16-5

2 – QLA2310/2310F/2310FLFCode2-8 FC2354601-00 EQ2.3.3Setting the QLA23xx HBA Loop IDWhen the QLA23xx HBA is currently operating in loop mode (through

Page 204 - Perform Target Binding

2 – QLA2310/2310F/2310FLFCodeFC2354601-00 E 2-9QThe new data rate displays. For example:Calculating NVRAM checksum, please wait... Current HBA data r

Page 205 - Confirm Configuration Changes

2 – QLA2310/2310F/2310FLFCode2-10 FC2354601-00 EQThe following displays:Calculating NVRAM checksum, please wait... doneBoot device login successfulB

Page 206 - HBA Configuration Status

2 – QLA2310/2310F/2310FLFCodeFC2354601-00 E 2-11QIf there were not at least 1.7 GB free on this disk, you would need to create a partition on the new

Page 207 - Exit Wizard Mode

2 – QLA2310/2310F/2310FLFCode2-12 FC2354601-00 EQ5. Change to the root partition mount point directory. For example:cd /mnt6. Use the ufsdump utility

Page 208 - 16-10 FC2354601-00 E

2 – QLA2310/2310F/2310FLSpecificationsFC2354601-00 E 2-13Q2.4SpecificationsTables 2-1 and 2-2 define the QLA23xx specifications.Table 2-1. QLA2310/23

Page 209 - Windows 2000

2 – QLA2310/2310F/2310FLLabel2-14 FC2354601-00 EQ2.5LabelThe transceiver on the QLA23xx HBA is a Class I laser product. It complies with IEC 825-1 an

Page 210

2 – QLA2310/2310F/2310FLAgency CertificationFC2354601-00 E 2-15Qn 89/336/EEC EMC Directive CEq EN55022:1995 Class Bq Radiated Emission Class Bq Condu

Page 211 - FC2354601-00 E 17-3

2 – QLA2310/2310F/2310FLAgency Certification2-16 FC2354601-00 EQ2.6.2QLA2310FThe following sections contain a summary of EMC/EMI test specifications

Page 212 - 17-4 FC2354601-00 E

2 – QLA2310/2310F/2310FLAgency CertificationFC2354601-00 E 2-17Q2.6.2.2Product Safety Requirementsn UL, cULq UL60950q CSA C22.2 No.60950q Class 1 Las

Page 213

SANblade 2300 Series User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersQPage iv FC2354601-00 E© 2002 QLogic Corporation. All rights reserved wo

Page 214

2 – QLA2310/2310F/2310FLAgency Certification2-18 FC2354601-00 EQq EN61000-3-2:1995 Harmonic Current Emissionq EN61000-3-3:1994 Voltage Fluctuation an

Page 215

FC2354601-00 E 3-1Section 3 QLA2340/2340L3.1QLA2340/2340L HBA ComponentsFigure 3-1 identifies the QLA2340/2340L HBA components referenced throug

Page 216 - 17-8 FC2354601-00 E

3 – QLA2340/2340LInstallation in the Computer3-2 FC2354601-00 EQ3.1.1LEDsFigure 3-2 identifies and describes the activity of the QLA2340/2340L HBA LE

Page 217 - FC2354601-00 E 17-9

3 – QLA2340/2340LInstallation in the ComputerFC2354601-00 E 3-3QPerform the following steps to install the QLA2340/2340L HBA in your PC:1. Check the

Page 218

3 – QLA2340/2340LInstallation in the Computer3-4 FC2354601-00 EQ9. Carefully reinstall the computer cover. Insert and tighten the computer cover scre

Page 219 - FC2354601-00 E 17-11

3 – QLA2340/2340LFCodeFC2354601-00 E 3-5QIf you have a selectable boot BIOS and want to boot to an FC hard disk, set the motherboard BIOS parameters

Page 220

3 – QLA2340/2340LFCode3-6 FC2354601-00 EQPerform the following steps to run the flash utility:1. Copy the qla2x00flash file and the ifp2312.prom file

Page 221 - FC2354601-00 E 17-13

3 – QLA2340/2340LFCodeFC2354601-00 E 3-7Q3.3.3Setting the QLA2340/2340L HBA Loop IDWhen the QLA2340/2340L HBA is currently operating in loop mode (th

Page 222

3 – QLA2340/2340LFCode3-8 FC2354601-00 EQTable 3-1 lists the values to enter and their corresponding data rates. QLogic recommends the Auto-negotiate

Page 223

3 – QLA2340/2340LFCodeFC2354601-00 E 3-9Q6. To boot the QLA2340/2340L HBA, type the complete boot path, including the loop ID and LUN. The loop ID an

Page 224 - 17-16 FC2354601-00 E

FC2354601-00 E Page vTable of ContentsSection 1 Introduction1.1 How to Use this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 225 - LUN List Tabbed Page

3 – QLA2340/2340LFCode3-10 FC2354601-00 EQtemporary saveset files. If you are not familiar with the format command, refer to the Solaris documentatio

Page 226

3 – QLA2340/2340LSpecificationsFC2354601-00 E 3-11Q8. Install the boot block on the new boot disk. For example:installboot /usr/platform/`uname -i`/l

Page 227

3 – QLA2340/2340LSpecifications3-12 FC2354601-00 EQTable 3-3. QLA2340/2340L HBA Specifications Type SpecificationHost bus Conforms to PCI Local Bus S

Page 228

3 – QLA2340/2340LAgency CertificationFC2354601-00 E 3-13Q3.5LabelThe transceiver on the QLA2340/2340L HBA is a Class I laser product. It complies wit

Page 229

3 – QLA2340/2340LAgency Certification3-14 FC2354601-00 EQn VCCI, Class B certifiedn CNS 13438 Class B certifiedn AS/NZS 3548 Class Bn Korea MIC certi

Page 230 - 17-22 FC2354601-00 E

FC2354601-00 E 4-1Section 4 QLA2342/2342L4.1QLA2342/2342L HBA ComponentsFigure 4-1 identifies the QLA2342/2342L HBA components referenced throug

Page 231

4 – QLA2342/2342LInstallation in the Computer4-2 FC2354601-00 EQ4.1.1LEDsFigure 4-2 identifies and describes the activity of the QLA2342/2342L HBA LE

Page 232

4 – QLA2342/2342LInstallation in the ComputerFC2354601-00 E 4-3QPerform the following steps to install the QLA2342/2342L HBA in your PC:1. Check the

Page 233 - FC2354601-00 E 17-25

4 – QLA2342/2342LInstallation in the Computer4-4 FC2354601-00 EQ9. Carefully reinstall the computer cover. Insert and tighten the computer cover scre

Page 234 - 17-26 FC2354601-00 E

4 – QLA2342/2342LFCodeFC2354601-00 E 4-5QIf you have a selectable boot BIOS and want to boot to an FC hard disk, set the motherboard BIOS parameters

Page 235 - FC2354601-00 E 17-27

SANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersPage vi FC2354601-00 EQSection 3 QLA2340/2340L3.1 QLA2340/2340L HBA Components

Page 236 - 17-28 FC2354601-00 E

4 – QLA2342/2342LFCode4-6 FC2354601-00 EQWARNING!! Be careful when changing flash contents; incorrect data may render the QLA2342/2342L HBA unusable

Page 237 - FC2354601-00 E 17-29

4 – QLA2342/2342LFCodeFC2354601-00 E 4-7QThe new connection mode displays. For example:Calculating NVRAM checksum, please wait... Current HBA connect

Page 238 - 17-30 FC2354601-00 E

4 – QLA2342/2342LFCode4-8 FC2354601-00 EQUse the set-data-rate command to change the current QLA2342/2342L Fibre Channel data rate. For example:ok 1

Page 239 - FC2354601-00 E 17-31

4 – QLA2342/2342LFCodeFC2354601-00 E 4-9QThe following displays:Calculating NVRAM checksum, please wait... doneBoot device login successfulBoot WWN

Page 240 - Update the NVRAM and BIOS

4 – QLA2342/2342LFCode4-10 FC2354601-00 EQIf there were not at least 1.7 GB free on this disk, you would need to create a partition on the new bootab

Page 241 - FC2354601-00 E 17-33

4 – QLA2342/2342LFCodeFC2354601-00 E 4-11Q6. Use the ufsdump utility to copy the root partition to the new book disk. For example:ufsdump 0f - / | uf

Page 242 - Updating the BIOS

4 – QLA2342/2342LSpecifications4-12 FC2354601-00 EQ4.4SpecificationsTables 4-2 and 4-3 define the QLA2342/2342L specifications.Table 4-2. QLA2342/234

Page 243 - FC2354601-00 E 17-35

4 – QLA2342/2342LAgency CertificationFC2354601-00 E 4-13Q4.5LabelThe transceiver on the QLA2342/2342L HBA is a Class I laser product. It complies wit

Page 244 - 17-36 FC2354601-00 E

4 – QLA2342/2342LAgency Certification4-14 FC2354601-00 EQq EN55024:1998q Immunity Standards q EN61000-4-2 :1995 ESD q EN61000-4-3 :1995 RF Electro M

Page 245

FC2354601-00 E 5-1Section 5 QLA23445.1QLA2344 HBA ComponentsFigure 5-1 identifies the QLA2344 HBA components referenced throughout this section.

Page 246

2-Gb Fibre Channel to PCI-XFC2354601-00 E Page viiQSANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersSection 5 QLA23445.1 QLA234

Page 247

5 – QLA2344Installation in the Computer5-2 FC2354601-00 EQ5.2Installation in the ComputerBefore you install the QLA2344 HBA in your computer, you nee

Page 248 - 18-4 FC2354601-00 E

5 – QLA2344Installation in the ComputerFC2354601-00 E 5-3Qn PCI connectors vary among system HBA manufacturers. The QLA2344 HBA is a 64-bit PCI devic

Page 249 - FC2354601-00 E 18-5

5 – QLA2344FCode5-4 FC2354601-00 EQSee section 14 for detailed instructions on how to customize the QLA2344 HBA and its attached devices using the Fa

Page 250

5 – QLA2344FCodeFC2354601-00 E 5-5Q4. Set the QLA2344 HBA data rate (see section 5.3.4).5. Select the boot device (see section 5.3.5).6. Build the bo

Page 251

5 – QLA2344FCode5-6 FC2354601-00 EQ5.3.2Setting the QLA2344 HBA Connection ModePerform the following steps to view the current QLA2344 HBA connection

Page 252

5 – QLA2344FCodeFC2354601-00 E 5-7Q5.3.3Setting the QLA2344 HBA Loop IDWhen the QLA2344 HBA is currently operating in loop mode (through connection m

Page 253 - FC2354601-00 E 18-9

5 – QLA2344FCode5-8 FC2354601-00 EQTable 5-1 lists the values to enter and their corresponding data rates. QLogic recommends the Auto-negotiated rate

Page 254 - 18-10 FC2354601-00 E

5 – QLA2344FCodeFC2354601-00 E 5-9Q6. To boot the QLA2344 HBA, type the complete boot path, including the loop ID and LUN. The loop ID and LUN must m

Page 255

5 – QLA2344FCode5-10 FC2354601-00 EQtemporary saveset files. If you are not familiar with the format command, refer to the Solaris documentation.WARN

Page 256 - 19-2 FC2354601-00 E

5 – QLA2344FCodeFC2354601-00 E 5-11Q7. Use the rm command to delete the restoresymtable file:rm restoresymtable8. Install the boot block on the new b

Page 257 - FC2354601-00 E 19-3

SANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus AdaptersPage viii FC2354601-00 EQPart II SoftwareSection 8 Windows NT Driver Installat

Page 258 - 19-4 FC2354601-00 E

5 – QLA2344Specifications5-12 FC2354601-00 EQ5.4SpecificationsTables 5-2 and 5-3 define the QLA2344 specifications.Table 5-2. QLA2344 HBA Operating E

Page 259 - FC2354601-00 E 19-5

5 – QLA2344Agency CertificationFC2354601-00 E 5-13Q5.5LabelThe transceiver on the QLA2344 HBA is a Class I laser product. It complies with IEC 825-1

Page 260 - 19-6 FC2354601-00 E

5 – QLA2344Agency Certification5-14 FC2354601-00 EQq EN55024:1998q Immunity Standards q EN61000-4-2 :1995 ESD q EN61000-4-3 :1995 RF Electro Magneti

Page 261 - Exiting SANblade Control VIX

FC2354601-00 E 6-1Section 6 QLA2350/23526.1QLA2350/2352 HBA ComponentsFigures 6-1 and 6-2 identify the QLA2350/2352 HBA components referenced th

Page 262 - 19-8 FC2354601-00 E

6 – QLA2350/2352QLA2350/2352 HBA Components6-2 FC2354601-00 EQFigure 6-2. QLA2352 HBA Layout6.1.1LEDsFigures 6-3 and 6-4 identify and describe the ac

Page 263 - Host Info Tabbed Page

6 – QLA2350/2352Installation in the ComputerFC2354601-00 E 6-3QFigure 6-4. QLA2352 HBA LED Activity6.1.2JumpersThe jumpers on the QLA2350/23452 HBAs

Page 264 - VI Tabbed Page

6 – QLA2350/2352Installation in the Computer6-4 FC2354601-00 EQenable HBAs, bus master slots, and IRQ levels. If the motherboard supports triggering,

Page 265

6 – QLA2350/2352Installation in the ComputerFC2354601-00 E 6-5Q10. Power up all external FC devices, then power up the PC and observe the monitor. Th

Page 266 - Link Status Tabbed Page

6 – QLA2350/2352Specifications6-6 FC2354601-00 EQSome new system BIOSs support selectable boot, which supersedes the QLA2350/2352 HBA BIOS selectable

Page 267 - Settings Tabbed Page

6 – QLA2350/2352Agency CertificationFC2354601-00 E 6-7Q6.4LabelThe transceiver on the QLA2350/2352 HBA is a Class I laser product. It complies with I

Page 268

2-Gb Fibre Channel to PCI-XFC2354601-00 E Page ixQSANblade 2300 User’s Guide2-Gb Fibre Channel to PCI-X Host Bus Adapters9.5.1 MaximumSGList . . .

Page 269

6 – QLA2350/2352Agency Certification6-8 FC2354601-00 EQn CE Mark 89/336/EEC EMC Directive q EN55022:1998/CISPR22:1997 Class Bq Radiated Emission Clas

Page 270 - 19-16 FC2354601-00 E

FC2354601-00 E 7-1Section 7 Troubleshooting7.1Problems After InstallationThere are three basic types of installation problems that can cause yo

Page 271 - FC2354601-00 E 19-17

7 – TroubleshootingSystem Configuration Problem Checklist7-2 FC2354601-00 EQ7.3System Configuration Problem ChecklistAll PCI-compliant and PCI-X-comp

Page 272 - 19-18 FC2354601-00 E

FC2354601-00 E II-1Part II SoftwareThis part of the SANblade 2300 User’s Guide describes how to install the software drivers for the supported o

Page 273 - Configuring the Host

II – SoftwareII-2 FC2354601-00 EQNotes

Page 274

FC2354601-00 E 8-1Section 8 Windows NT Driver Installation(QL2300.SYS)8.1IntroductionThis section provides instructions for installing the Windo

Page 275

8 – Windows NT Driver InstallationWindows NT Driver Installation8-2 FC2354601-00 EQ8.3.1Initial Installation of Windows NT and the Windows NT Driver

Page 276 - Performing Diagnostics

8 – Windows NT Driver InstallationSystem Registry ParametersFC2354601-00 E 8-3Q8.3.3Updating the Windows NT DriverPerform the following steps if a Wi

Page 277 - FC2354601-00 E 19-23

8 – Windows NT Driver InstallationSystem Registry Parameters8-4 FC2354601-00 EQTo change this value, follow these steps:1. Click Start, select Run, a

Page 278 - 19-24 FC2354601-00 E

8 – Windows NT Driver InstallationSystem Registry ParametersFC2354601-00 E 8-5QFollow these steps to disable OS support for more than eight LUNs:1. C

Commentaires sur ces manuels

Pas de commentaire