EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows Environment
Planning, Miscellaneous Procedures, and Troubleshooting
Figure 2-2 SANsurfer iSCSI HBA Manager, HBA Options
Configuring iSNS settings for QLA4010
For iSNS support, the QLA4010 must be running the correct driver
(see the EMC Support Matrix for latest version.)
Targets must register with the iSNS server. To register, enable the
iSNS server and enter the IP address using the SANsurfer iSCSI
HBA Manager, HBA Options, Network, Enable iSNS dialog box.
Click Save HBA under the Network tab on the SANsurfer iSCSI
HBA Manager, HBA Options tab.
The target should be detected by SANsurfer and shown on the SAN-
surfer iSCSI HBA Manager, Target Settings tab. Click SAVE Set-
tings to bind the targets. If the targets are not detected, follow these