Page ii 59055-00 B
D
SANbox 5200 Fibre Channel Switch
Installation Guide
© 2000–2004 QLogic
First Printed: August 2003
All Rights Reserved Worldwide.
Printed in U.S.A.
Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no
responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its
use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications
described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no
representation nor warranty that such applications are suitable for the specified use without further testing or
modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
QLogic, SANbox, SANbox Manager, SANblade, SANsurfer, SANsurfer Management Suite, and Multistage are
trademarks or registered trademarks of QLogic Corporation.
General Devices is trademark of General Devices Company, Inc.
Gnome is a trademark of the GNOME Foundation Corporation.
Java and Solaris are registered trademarks of Sun Microsystems, Inc.
Linux is a registered trademark of Linus Torvalds.
Microsoft, Windows NT, and Windows 2000/2003, and Internet Explorer are registered trademarks of Microsoft
Corporation.
Motorola is a registered trademark of Motorola, Inc.
Netscape Navigator and Mozilla are trademarks or registered trademarks of Netscape Communications
Corporation.
PowerPC is registered trademark of International Business Machines Corporation.
Red Hat is a registered trademark of Red Hat Software Inc.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Document Revision History
Release, Revision A, November 2003
Update, Revision B, January 2004
Change Affected Section
Fan status is not monitored or reported 2.5
XPAK cable is renamed XPAK switch stacking
cable.
2.2, 3.5.2.1, A.1
Adjusted credit loss when extending credits 3.3.1
XPAK switch stacking cable installation
instructions
4.2.2
User accounts are not stored in configdata file B.3.2
Alarm log is cleared when switch is reset or power
cycled
”Hardreset Command” on page B-16
”Hotreset Command” on page B-19
”Reset Command” on page B-26
”Show Command” on page B-55
Set Alarm Clear requires an Admin session ”Set Command” on page B-31
Enable I/O Stream Guard only on initiators
FC-SW Auto Save recommendations
”Set Config Command” on page B-33