Qlogic Fibre Channel NPIV Storage Networking Guide Spécifications

Naviguer en ligne ou télécharger Spécifications pour Mise en réseau Qlogic Fibre Channel NPIV Storage Networking Guide. Qlogic Fibre Channel NPIV Storage Networking Guide Product specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 78
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
FC0054608-00 A
FC0054608-00 A
Fibre Channel NPIV Storage Networking
for Windows Server 2008 R2 Hyper-V
and System Center VMM2008 R2
Usage Scenarios and Best Practices Guide
Vue de la page 0
1 2 3 4 5 6 ... 77 78

Résumé du contenu

Page 1 - FC0054608-00 A

FC0054608-00 A FC0054608-00 A Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2 Us

Page 2

I-Deployment Best Practices for NPIV SAN Migration I-2 Notes

Page 3 - Table of Contents

1-1 1 Introduction Abstract This guide describes procedures and best practices for planning and deploying N_Port ID Virtualization (NPIV)

Page 4 - Part III

1-Introduction Microsoft Windows Server 2008 R2 Hyper-V 1-2 The deployment scenario in this document demonstrates NPIV VM migration in a SAN-att

Page 5 - FC0054608-00 A v

1-Introduction System Center Virtual Machine Manager 1-3 Machine Manager 2008 R2, helps realize the vision of the dynamic data center. Follow t

Page 6

1-Introduction N_Port ID Virtualization (NPIV) 1-4 This document focuses on NPIV SAN migration. N_Port ID Virtualization (NPIV) N_Port ID Virtu

Page 7 - Preface

1-Introduction Value of NPIV in IT Strategy and Best Practices 1-5 Value of NPIV in IT Strategy and Best Practices Fibre Channel NPIV technolog

Page 8 - Documentation Conventions

1-Introduction QLogic Fibre Channel Adapter NPIV Solution 1-6 With the combined QLogic and Microsoft solution, storage administrators can create

Page 9 - SAN Migration

1-Introduction NPIV VMM2008 R2 SAN Migration Steps 1-7 NPIV VMM2008 R2 SAN Migration Steps The chart in How to Enable SAN Migration outlines th

Page 10 - I-2

1-Introduction NPIV VMM2008 R2 SAN Migration Steps 1-8 Notes

Page 11 - 1 Introduction

2-1 2 NPIV SAN Migration: Server Preparation This section list the hardware and software requirements that must be met before deploying t

Page 12 - 1-2

Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2─Usage Scenarios and Best Practices Guide ii

Page 13 - 1-3

2-NPIV SAN Migration: Server Preparation Software Requirements 2-2 http://technet.microsoft.com/en-us/library/cc764224.aspx#UpTo Software Requir

Page 14 - 1-4

2-NPIV SAN Migration: Server Preparation Sample Solution Configuration 2-3 Sample Solution Configuration Figure 2-1 Quick Migration Configurati

Page 15 - 1-5

2-NPIV SAN Migration: Server Preparation Installing the Software 2-4 1. Install Windows Server 2003 R2 SP2 and set it up as the domain controll

Page 16 - 1-6

2-NPIV SAN Migration: Server Preparation Installing the Software 2-5 3. Activate the required Windows Server 2008 R2 roles, services, and feat

Page 17 - 1-7

2-NPIV SAN Migration: Server Preparation Installing the Software 2-6 Figure 2-4. Details of the Hyper-V Role

Page 18 - 1-8

2-NPIV SAN Migration: Server Preparation Installing the Software 2-7 The installed server features are summarized in Figure 2-5. They are consi

Page 19 - 2 NPIV SAN Migration:

2-NPIV SAN Migration: Server Preparation Installing the Software 2-8 NOTE: In addition to enabling the Multipath I/O feature, ensure that the st

Page 20 - Software Requirements

3-1 3 Fibre Channel SAN Preparation Introduction This section assumes that you are familiar with QLogic‘s SANsurfer FC HBA Manager tool a

Page 21 - Installing the Software

3-Fibre Channel SAN Preparation Virtual Host Bus Adapter Port Creation and SAN Zoning 3-2 Alternatively, the SAN can be configured as two zones,

Page 22 - 2-4

3-Fibre Channel SAN Preparation Host Presentation (Mapping) of Storage LUN 3-3 The zoning configuration in Figure 3-2 shows two adapter ports:

Page 23 - 2-5

iii Table of Contents Preface Intended Audience ... vii Documen

Page 24 - 2-6

3-Fibre Channel SAN Preparation Host Presentation (Mapping) of Storage LUN 3-4 After creating a LUN, mount a volume in the LUN. (For more inform

Page 25 - 2-7

3-Fibre Channel SAN Preparation Host Presentation (Mapping) of Storage LUN 3-5 In Figure 3-4, the LUN is mapped/presented/masked to the host 21

Page 26 - Figure 2-6. MPIO Properties

3-Fibre Channel SAN Preparation Host Presentation (Mapping) of Storage LUN 3-6 View the Storage Manager for SANs snap-in to confirm that the LUN

Page 27 - 3 Fibre Channel SAN

4-1 4 VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration Microsoft System Center VMM2008 R2 is used for the creation and migration of

Page 28 - 3-2

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-2 Figure 4-1. Hosts Added to VMM2008 R2 In Figure 4-1, the hosts win-3f1

Page 29 - 3-3

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-3 VMM2008 R2 automatically mounts the appropriate volumes during the migr

Page 30 - 3-4

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-4 In this example, a new VM will be created on a blank virtual hard disk (

Page 31 - 21:f9:00:1b:32:16:fe:ec

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-5 4. Configure the hardware profile for the VM (see Figure 4-4). Figure

Page 32 - 3-6

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-6 5. Click Next until the Select Destination dialog box opens. Ensure th

Page 33 - 4 VMM2008 R2 Setup, VM

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-7 7 Click Next. The Select Path dialog box opens (see Figure 4-6). By d

Page 34 - VM Creation

Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2─Usage Scenarios and Best Practices Guide iv

Page 35 - Figure 4-2. Select Source

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-8 Figure 4-7 is an example of the Summary page that displays the VM settin

Page 36 - 4-4

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-9  Format the volume with the NTFS file system. When performing SAN tra

Page 37 - 4-5

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-10 Similarly, as shown in Figure 4-9, there are no VMs on the second host

Page 38

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-11 VM Migration As shown in Figure 4-10, VM migration is invoked by righ

Page 39 - Figure 4-6. Select Path

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-12 The Migration Virtual Machine Wizard opens and leads you through the f

Page 40 - Figure 4-7. Summary

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-13 The Select Path dialog box opens (Figure 4-12). Figure 4-12. Select

Page 41 - 4-9

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-14 4. Click Next when you are done. 5. The Summary dialog box opens (F

Page 42 - 3fikc24knkr

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-15 7. Click Jobs to see the details of the migration (see Figure 4-14)

Page 43 - VM Migration

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration NPIV SAN Migration Confirmation 4-16 NPIV SAN Migration Confirmation After migration, us

Page 44 - 4-12

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration NPIV SAN Migration Confirmation 4-17 After migration, the selected VM (vm22) is now hos

Page 45 - 4-13

Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2 — Usage Scanarios and Best Practices Guide F

Page 46 - Review the summary

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration NPIV SAN Migration Confirmation 4-18 Windows Server Disk Management validates that the v

Page 47 - 4-15

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration Using Fibre Channel NPIV Technology — Key Conclusions 4-19 Using Fibre Channel NPIV Tec

Page 48 - (see Figure 4-15)

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration Using Fibre Channel NPIV Technology — Key Conclusions 4-20 Notes

Page 49 - 4-17

II-1 Part II Resolving Fibre Channel Adapter Saturation on Hyper-V Workloads This part of the document contains the following section: 

Page 50 - Figure 4-17)

II-Resolving Fibre Channel Adapter Saturation on Hyper-V Workloads II-2 Notes

Page 51 - Conclusions

5-1 5 QLogic Management PRO Pack and NPIV Technology Overview Increasing server consolidation results in multiple workloads exercising t

Page 52 - 4-20

5-QLogic Management PRO Pack and NPIV Technology Solution 5-2 http://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/SearchByProduct.aspx?Pr

Page 53

5-QLogic Management PRO Pack and NPIV Technology PRO Pack Benefits 5-3 A PRO Tip is generated when a virtual or physical port‘s IOPS or data ra

Page 54 - II-2

5-QLogic Management PRO Pack and NPIV Technology PRO Pack Benefits with NPIV Deployments 5-4  Dynamic and automated IT agility  Single glass

Page 55 - 5 QLogic Management PRO

5-QLogic Management PRO Pack and NPIV Technology PRO Pack Benefits with NPIV Deployments 5-5 Notes

Page 56 - 5-2

Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2─Usage Scenarios and Best Practices Guide vi

Page 58 - 5-4

III-1 Part III Using the Hyper-V Pass-through Disk Option This part of the document contains the following section:  Section 6, Hyper-V

Page 59 - 5-5

III-Using the Hyper-V Pass-through Disk Option III-2

Page 60

6-1 6 Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Overview A Hyper-V host server running Windows Server 2008 R

Page 61

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration 6-2 The combination of QLogic Fibre Channel adapters (with

Page 62 - III-2

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-3 Configuration Steps Follow these steps to prese

Page 63 - 6 Hyper-V Pass-Through

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-4 3. Create two VMs using the Windows Server 2008

Page 64 - Configuration

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-5 4. Initialize the two storage LUNs on the Hype

Page 65 - Configuration Steps

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-6 5. Add the LUNs as pass-through storage disks f

Page 66 - 6-4

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-7 6. Map (present) each of the two VM LUNs to ea

Page 67 - 6-5

vii Preface Intended Audience This guide is for data center system administrators and IT managers working with Microsoft® Windows Server®

Page 68 - SCSI controller

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-8 7. Map the two pass-through storage LUNs to the

Page 69 - Port 21-F9-00-1B-32-16-FE-EC

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-9 NOTE: Ensure th

Page 70 - 6-8

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-10 Figure 6-8. T

Page 71 - Service

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-11 Figure 6-9.

Page 72 - Channel Port 0

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-12 Figure 6-10.

Page 73 - 6-11

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-13 Figure 6-11.

Page 74 - 6-12

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Summary and Conclusions 6-14 Figure 6-12. Priority (High/Medium/Low) B

Page 76 - Summary and Conclusions

© 2009 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic, the QLogic logo, and SANsurf

Page 77

Preface Documentation Conventions viii  Click the Start button, point to Programs, point to Accessories, and then click Command Prompt.  Und

Page 78

I-1 Part I Deployment Best Practices for NPIV SAN Migration This part of the document contains the following sections:  Section 1, Intro

Commentaires sur ces manuels

Pas de commentaire