Qlogic Storage Networking (Unified Fabric Pilot) Guide d'installation Page 60

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 76
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 59
5–Validation Methods for DCB and FCoE
Validation Step 7—Virtualization Verification
5-30 51031-00 A
6. Configure the test as follows:
Trigger: any PFC frame
Post fill: 90 percent after the trigger
Data size: 512K
Traffic: 100 percent read on both virtual machines
7. Use Analyzer to capture a trace.
8. Use Expert to analyze the trace, and calculate the average, minimum, and
maximum throughput results per priority.
9. Compare I/O performance for the two virtual machines.
Repeat the entire test, using separate hosts for the iSCSI initiator and the FCoE
initiator, and compare I/O performance.
Validation Results
One virtual machine ran the FCoE read application, and the other virtual machine
ran the iSCSI read application. Figure 5-31 shows the throughput results for
individual and combined applications.
Figure 5-31. FCoE and iSCSI Application Throughput in a Virtual Environment
iSCSI throughput increases when
FCoE traffic decreases in the absence
of PFC pauses